Triton Isis Manuel d'utilisateur Page 259

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 310
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 258
June 2004 Isis® Sonar User's Manual, Volume 1
245
Figure 10-11: Bathymetry True 3-D Display Settings
Select Channels: usually just one head for multibeam; head #2 can be set
when surveying with a dual-head multibeam sonar.
Correct for: Data - telemetry from sensors or offsets from sonar set-up are
applied to correct multibeam data.
Attitude: Pitch and Roll values from telemetry sensors are
applied to data.
Heave: Heave motion of fish or vessel is applied.
Depth: Depth of multibeam head, as read from the installation
offsets during acquisition. Offset values cannot be changed
during playback.
Color Palette: Six options for color. Checking Reverse will reverse the
palette.
Chapter 10: Using the Window Menu